Example:

# show port module 1
Status......................................... OK
Gigabit Ethernet Compliance Codes.............. 10GBASE-SR
Vendor Name.................................... FINISAR CORP.
Vendor Part Number............................. FTLX8571D3BCL-ME
Vendor Serial Number........................... UDD01@A
Vendor Revision Number......................... A
#

3.7.4 show port test (ADMIN)

Synopsys:

show port test port_number

Description:
Show test mode on the specified downlink port port_number.

Example:

& show port test 4
port 4 test off
& show port test 6
port 6 prbs31 on: 0 errors

3.8

Debug Commands

3.8.1 cr_read (ADMIN)

Synopsys:

cr_read device_number 0xaddress [number_of_

registers

]

Description:
Read one or more internal PhyX device register. This command accepts the following parameters:
• device_number – the device from which to read a register (1..3)
• address – the register memory location from which to read (32-bit address)number_of_registers

(Optional) - Specifies the number of registers to read (default 1)

Example:

& cr_read 2 0xf0014

0x000f0014:0x00a217d4

3.8.2 cr_write (ADMIN)

Synopsys:

cr_write device_number 0xaddress 0xdata

Advertising