General, Rack mount drive – Dell PowerVault LTO3-080 User Manual

Page 37

Advertising
background image

Back to Contents Page

Maximum wet bulb temperature

26°C (79°F) 

Maximum altitude

3048 m (10,000 ft)

Nonoperating Limits (Storage or Shipping)

Temperature

-40° to 60°C (-40° to 140°F) 

Humidity

10% to 90% relative humidity (noncondensing)

Maximum wet bulb temperature

26°C (79°F) 

Rack Mount Drive

Physical Specifications

Width

48.3 cm (19.0 in)

Length

44.0 cm (17.32 in)

Height

9.0 cm (3.54 in)

Weight

10.23 kg (22.55 lb) Chassis empty

Power Requirements

AC line voltage

100– 100-240 VAC

Line frequency

50–60 Hz, auto-ranging

Line current at 100 VAC

1.9A

Line current at 240 VAC

0.8A

Performance

Interface

6Gb SAS

Recording format

LTO Ultrium Generation

Media

LTO Ultrium

Capacity

LTO5-1500 GB (native) 3000 GB (compressed, assuming 2:1 compression)

LTO4-800 GB (native) 1600 GB (compressed, assuming 2:1 compression)

LTO3-400 GB (native) 800 GB (compressed, assuming 2:1 compression)

Data transfer rate (maximum)

LTO5-140 MB/sec Native

LTO4-120 MB/sec Native

LTO3-80 MB/sec Native

Burst transfer rate

up to 600 MB/sec

Operating Limits

Temperature

10° to 38°C (50° to 100°F) 

Humidity

20% to 80% relative humidity (noncondensing)

Maximum wet bulb temperature

26°C (79°F) 

Maximum altitude

3048 m (10,000 ft)

Nonoperating Limits (Storage or Shipping)

Temperature

-40° to 60°C (-40° to 140°F) 

Humidity

10% to 90% relative humidity (noncondensing)

Maximum wet bulb temperature

26°C (79°F) 

Advertising