Dell POWEREDGE M1000E User Manual

Page 75

Advertising
background image

Access Gateway Administrator’s Guide

55

53-1001760-01

Trunking in Access Gateway mode

3

Trunk area

The port must be disabled before assigning a Trunk Area on the
Edge switch to the port or removing a Trunk Area from a trunk
group.

You cannot assign a Trunk Area to ports if the standby CP is
running a firmware version earlier than Fabric OS V6.2.0.

PWWN

The entire Trunk Area trunk group share the same Port WWN
within the trunk group. The PWWN is the same across the F_Port
trunk that will have 0x2f or 0x25 as the first byte of the PWWN.
The TA is part of the PWWN in the format listed in

Table 9

on

page 57.

Downgrade

You can have trunking on, but you must disable the trunk ports
before performing a firmware downgrade.

Note: Removing a Trunk Area on ports running traffic is disruptive.
Use caution before assigning a Trunk Area if you need to
downgrade to a firmware earlier than Fabric OS v6.1.0.

Upgrade

No limitations on upgrade to Fabric OS v6.4.0 if the F_Port is
present on the switch. Upgrading is not disruptive.

HA Sync

If you plug in a standby-CP with a firmware version earlier than
Fabric OS v6.1.0 and a Trunk Area is present on the switch, the CP
blades will become out of sync.

Port Types

Only F_Port trunk ports are allowed on a Trunk Area port. All other
port types that include F/FL/E/EX are persistently disabled.

Default Area

Port X is a port that has its Default Area the same as its Trunk
Area. The only time you can remove port X from the trunk group is
if the entire trunk group has the Trunk Area disabled.

portCfgTrunkPort port, 0

portCfgTrunkPort port, 0 will fail if a Trunk Area is enabled on a
port. The port must be Trunk Area-disabled first.

switchCfgTrunk 0

switchCfgTrunk 0 will fail if a port has TA enabled. All ports on a
switch must be TA disabled first.

Port Swap

When you assign a Trunk Area to a trunk group, the Trunk Area
cannot be port swapped; if a port is swapped, then you cannot
assign a Trunk Area to that port.

Trunk Master

No more than one trunk master in a trunk group. The second
trunk master will be persistently disabled with reason “Area has
been acquired”.

Fast Write

When you assign a Trunk Area to a trunk group, the trunk group
cannot have fast write enabled on those ports; if a port is fast
write enabled, the port cannot be assigned a Trunk Area.

FICON

FICON is not supported on F_Port trunk ports. However, FICON
can still run on ports that are not F_Port trunked within the same
switch.

FC8-48 blades

F_Port Trunking does not support shared area ports on the
Brocade FC8-48 blades in a 48000. F_Port Trunking is supported
on all ports on the Brocade FC8-48 in the DCX and DCX-4S.

TABLE 8

Access Gateway trunking considerations for the Edge switch (Continued)

Category

Description

Advertising