Troubleshooting
A
NOTE
If a Fabric OS switch is in AG mode and is also set to McDATA Fabric mode, when that switch is 
connected to an M-EOS switch, the Fabric OS switch does not display in the output when you run the 
agshow command.
Failover is not working
Failover disabled on N_Port.
Verify that the failover and failback policies are enabled, as follows:
Enter the ag 
--
failoverShow command with the port_number
operand.
Enter the ag 
--
failbackShow command with the port_number
operand.
Command returns “Failback (or Failover) on N_Port port_number is 
supported.” 
If it returns, “Failback (or Failover) on N_Port port_number is not 
supported.” See 
“F_Ports automatically fail over to any available
Access Gateway is mode 
not wanted
Access Gateway must be disabled.
Disable switch using the switchDisable command.
Disable Access Gateway mode using 
the ag 
--
modeDisable command.
Answer yes when prompted; the switch reboots.
Log in to the switch. 
Display the switch settings using the switchShow command. Verify 
that the field switchMode displays Fabric OS Native mode.
“Login Rejected by FC 
stack” messages on 
console may be seen 
during F_Port and N_Port 
disruptions on Brocade 
8000 in AG Mode.
The CNA host is retrying a log in before 
the switch has finished precessing a 
previous fabric logout (LOGO) attempt. 
Working as designed. After the switch has completed LOGO 
processing, it will accept another login. 
TABLE 10
Troubleshooting (Continued)
Problem Cause
Solution