Dell PowerEdge C5125 User Manual
Page 14
Advertising
14
ID LED
Blue
Off
Normal status (by IPMI
Chassis Identify
command or System
ID Button)
Turn off the ID LED.
1. ipmitool raw 0x00 0x04
0x00
2. ipmitool raw 0x00 0x04
0x00 0x00
Solid On 1. Via IPMI chassis
command.
2. System id button
press.
Turn on the ID LED.
1.ipmitool raw 0x00 0x04
0x3c 01
Blinking Via IPMI Chassis
Identify command
1. IPMI chassis identify
command without request
data ipmitool raw 0x00 0x04
2. IPMI chassis identify
command with only 1
parameter data ipmitool raw
0x00 0x04 0x3c (blink 60
sec)
3. IPMI chassis identify
command with 2 parameter
data ipmitool raw 0x00 0x04
0x3c 0x00 (blink 60 sec)
Heartbeat
LED
Green Off
BMC is not ready
Blinking BMC is ready
Table 1-4. LED Status
LED
Color Status
Occurence
Note