Fan control and monitoring – Dell PowerEdge C5125 User Manual
Page 22

22
FAN Control and Monitoring
The BMC receives all fan tachometers of the threshold base from the chassis
controller. The following is the table of the fan speed thresholds.
8 Sled SKU
12 Sled SKU
Table 1-10. 8 Sled SKU Fan Thresholds
Fan Sensor
Sensor
Number
LCT
LNCT
UNCT
UCT
SYS FAN 1
68h
0rpm
660rpm
N/A
N/A
SYS FAN 2
69h
0rpm
660rpm
N/A
N/A
SYS FAN 3
6Ah
0rpm
660rpm
N/A
N/A
SYS FAN 4
6Bh
0rpm
660rpm
N/A
N/A
SYS FAN 5
6Ch
0rpm
660rpm
N/A
N/A
SYS FAN 6
6Dh
0rpm
660rpm
N/A
N/A
SYS FAN 7
6Eh
0rpm
660rpm
N/A
N/A
SYS FAN 8
6Fh
0rpm
660rpm
N/A
N/A
Table 1-11. 12 Sled SKU Fan Thresholds
Fan Sensor
Sensor
Number
LCT
LNCT
UNCT
UCT
SYS FAN 1
68h
0rpm
1140rpm
N/A
N/A
SYS FAN 2
69h
0rpm
1140rpm
N/A
N/A
SYS FAN 3
6Ah
0rpm
1140rpm
N/A
N/A
SYS FAN 4
6Bh
0rpm
1140rpm
N/A
N/A
SYS FAN 5
6Ch
0rpm
1140rpm
N/A
N/A
SYS FAN 6
6Dh
0rpm
1140rpm
N/A
N/A
SYS FAN 7
6Eh
0rpm
1140rpm
N/A
N/A
SYS FAN 8
6Fh
0rpm
1140rpm
N/A
N/A