Dell PowerEdge C5125 User Manual
Page 15

15
Table 1-5. Blinking Fault LED Conditions
Index
Sensor Name
Event Triggers
1
CPU0_Temp,
• Upper Critical Going High.
• Upper Non-Critical Going High.
Ambient0_Temp,
DIMM Local Temp,
Rear Temp 1
Rear Temp 2
Rear Temp 3
2
BMC Watchdog
• Time expired
• Hard reset
• Power down
• Power cycle
3
Processor
Thermal trip
4
BMC SEL
• SEL almost full
• SEL Full
5
Processor Hot
State Asserted
6
POST Error
System firmware error
7
Critical Interrupt
PCI SERR
8
DIMM-A0
• Correctable error
• Uncorrectable error
• Correctable ECC error logging limit reached
DIMM-B0
DIMM-A1
DIMM-B1
9
SYS FAN 1 ~
SYS FAN 8
• Lower critical going low
• Lower non-critical going low
10
PSU 1 Status
PSU 2 Status
• Presence detected
• TEMPERATURE Failure detected
• IOUT Failure detected
• VOUT Failure detected
• FANS Failure detected
• INPUT Failure detected