Dell PowerEdge C6220 User Manual

Page 56

Advertising
background image

56

FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X

BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm

Table 1-37. Chassis Device Commands (NetFn: 00H)

Command

NetFn

CMD

O/M

Supported

Get Chassis Capabilities

Chassis

00h

M

Yes

Get Chassis Status

Chassis

01h

M

Yes

Chassis Control

Chassis

02h

M

Yes

Chassis Reset

Chassis

03h

O

No

Chassis Identify

Chassis

04h

O

Yes

Set Chassis Capabilities

Chassis

05h

O

Yes

Set Power Restore Policy

Chassis

06h

O

Yes

Get System Restart Cause

Chassis

07h

O

Yes

Set System Boot Options

Chassis

08h

O

Yes

Get System Boot Options

Chassis

09h

O

Yes

Set Front Panel Button Enable

Chassis

0Ah

O

Yes

Set Power Cycle Interval

Chassis

0Bh

O

Yes

Get POH Counter

Chassis

0Fh

O

No

Table 1-38. PEF/PET Alerting Commands (NetFn: 04H)

Command

NetFn

CMD

O/M

Supported

Get PEF Capabilities

S/E

10h

M

Yes

Arm PEF Postpone Timer

S/E

11h

M

Yes

Set PEF Configuration Parameters

S/E

12h

M

Yes

Get PEF Configuration Parameters

S/E

13h

M

Yes

Set Last Processed Event ID

S/E

14h

M

Yes

Get Last Processed Event ID

S/E

15h

M

Yes

Alert Immediate

S/E

16h

O

Yes

PET Acknowledge

S/E

17h

O

Yes

Advertising