Threshold settings and converting formulas – Dell PowerEdge C6220 User Manual
Page 77

77
FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X
BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm
Threshold Settings and Converting Formulas
The following table lists the system sensor’s threshold settings and formulas
for converting the sensor readings.
Table 1-62. Threshold Settings and Converting Formulas
Sensor
Number
Sensor Name The Converting Formula
Upper non-
recoverable
Upper
critical
Upper
non-
critical
Lower non-
recoverable
Lower
critical
Lower
non-
critical
Voltage
05h
12 V Standby Actual_Reading (Volts) = ((Raw_Data x 65) + 60) x 0.001
D4
CA
C1
9C
A6
AF
06h
5 V
Actual_Reading (Volts) = ((Raw_Data x276) + 100) x
0.0001
D0
C7
BE
9A
A3
AC
07h
5 V Standby Actual_Reading (Volts) = ((Raw_Data x 277) + 80) x
0.0001
D0
C7
BE
9A
A3
AC
08h
3.3 V
Actual_Reading (Volts) = ((Raw_Data x 199) + 70) x
0.0001
BF
B7
AE
8D
95
9E
09h
3.3 V Standby Actual_Reading (Volts) = ((Raw_Data x 197) + 100) x
0.0001
C1
B9
B0
8F
97
A0