Dell PowerEdge C6220 User Manual

Page 69

Advertising
background image

69

FILE LOCATION: D:\Projects\User Guide\Server\Dell\OOB\HOM\C8220-C8220X

BMC\BMC\C8220-C8220X_BMC_HOM_section1.fm

DNS Register

BMC

4

1

Enable registering the BMC host name to the

DNS server (via DHCP Request Option 81h -

FQDN)

• 0: FALSE (default)
• 1: TRUE

R/W

DNS BMC Host

Name

5

1..

64

Specifies the DNS BMC host name. When the

DNS Register BMC is set to TRUE this parameter

is read-only. At least one character must be

alphabetic.
The default name is bmc-<service_tag>-

<rack_id>-<chassis_id>-<sled_id>, where

service_tag is the service tag number of the Dell

server. For example: bmc-XG3487A-00-00-01.

R/W

DNS Domain

Name DHCP

Enable

6

1

Specifies that the DNS domain name should be

assigned from the DHCP server.

• 0: FALSE (default)
• 1: TRUE

R/W

DNS Domain

Name

7

1.25

6

The DNS domain name string. When the DNS

Domain Name DHCP Enable is set to TRUE this

parameter is read-only.
Characters are restricted to alphanumeric,

'-' and '.'. Default value is "".

R/W

DNS

Registration

Delay

8

1

This is the delay that BMC should take 'after' the

IPMI process is up and running. This delay will

allow SC to dispatch information necessary to

compose BMC's host name, i.e. rack ID, chassis

ID, and sled ID. Default value is 5 seconds.

R/W

Table 1-54. Configuration ID = 06h, DNS

Attribute

ID Size Description

R/W

Advertising