Dell PowerVault 124T User Manual

Page 45

Advertising
background image

17

Activate Error

18

Threshold Error

19

Suspend Lifted

1A

Block Pool Error

1B

Queue Function Failed

1C

Semaphore Function Failed

1D

Timer Function Failed

1F

Thread Function Failed

20

Command Started

21

System Failure

22

System Busy

23

System Timeout

24

Software Error

25

Hardware Error

Message Error Types

26

Message Sender (Task ) ID
Error

l

Verify the host backup application and device driver are at the latest supported revision at

support.dell.com

.

l

Check host adapter and SAS cables.

l

Power cycle the autoloader and retry the operation.

l

If all previous steps fail, see

Contacting Dell

.

27

Message Type Bad

28

Message Parameter Bad

Stack/Global Data Corruption Error Types

29

Invalid Element

l

Verify the host backup application and device driver are at the latest supported revision at

support.dell.com

.

l

Power cycle the autoloader.

l

Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).

Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.

l

If all previous steps fail, see

Contacting Dell

.

2A

Invalid Element Status   

2B

Element Table Bad

2C

Global Data Bad

2D

Stack Data Bad

2E

Task Stack Low

2F

Task Stack Overflow

System Shutdown/Disruption Error Types

30

POST Failure

l

Verify that the magazines/magazine blank are fully seated.

l

Power cycle the autoloader.

l

If all previous steps fail, see

Contacting Dell

.

31

Watchdog Timer

l

Power cycle the autoloader.

l

Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).

Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.

l

Check

support.dell.com

for PowerVault 124T firmware updates.

l

see

Contacting Dell

.

32

Power Event

33

Power Down Failure

34

System Overload

35

System Performance

36

Asynchronous Stop

System Miscellaneous Error Types

37

System Cleaning Error

Cleaning slot in use.

l

Verify that a valid cleaning cartridge is located in the dedicated cleaning slot indicated within the
Remote Management Unit Configuration page settings.

l

Check

support.dell.com

for PowerVault 124T firmware updates.

l

If all previous steps fail, see

Contacting Dell

.

38

System Internal I2C HW Error

See

Contacting Dell

.

39

ALD (Autoloader Diagnostic)
Limits Error

This error may occur as a result of a failed diagnostic test.

l

If the Magazine Test or Inventory Test failed, remove and inspect the magazines
one at a time. Turn the white thumbwheels on each magazine and insure that the carriers move
freely at
least one full rotation in each direction. Re-insert each magazine after inspection.

l

If the Picker Test failed, verify there is no obstruction within the picker assembly and repeat the test.