Back-panel indicators and features, Figure 2, Table 2 – Dell PowerEdge 2850 User Manual

Page 14

Advertising
background image

Table 2

-3

lists the drive indicator patterns. Different patterns are displayed as drive events occur in the system. For example, if a hard-drive fails, the "drive

failed" pattern appears. After the drive is selected for removal, the "drive being prepared for removal" pattern appears, followed by the "drive ready for
insertion or removal" pattern. After the replacement drive is installed, the "drive being prepared for operation" pattern appears, followed by the "drive online"
pattern.

 

Table 2-3. Hard-Drive Indicator Patterns 

 

Back-Panel Indicators and Features

Figure 2

-3

shows the back-panel features of the system.

Table 2

-4

describes the back-panel features.

 

Figure 2-3. Back-Panel Features

 

Table 2-4. Back-Panel Features

NOTE:

If RAID is not activated, only the "drive online" indicator pattern appears. The drive-activity indicator also blinks when the drive is being accessed.

 

Condition

 

Indicator Pattern

Identify drive

The green power-on/fault indicator blinks four times per second.

Drive being prepared for removal

The green power-on/fault indicator blinks two times per second.

Drive ready for insertion or removal Both drive indicators are off.

Drive being prepared for operation The green power-on/fault indicator is on.

Drive predicted failure

The power-on/fault indicator slowly blinks green, amber, and off.

Drive failed

The amber power-on/fault indicator blinks four times per second.

Drive rebuilding

The green power-on/fault indicator blinks slowly.

Drive online

The green power-on/fault indicator is on.

 

Component

 

Description

Power supply indicators

Provides information on power status. See "

Power Indicator Codes

."

NIC indicators

Provides information on NIC status. See "

NIC Indicator Codes

."

Advertising