Dell PowerEdge RAID Controller H710 User Manual

Page 19

Advertising
background image

Source RAID

Level

Target RAID Level Number of

Physical Disks

(Beginning)

Number of

Physical Disks

(End)

Capacity

Expansion

Possible

Description

disk into a
mirrored virtual
disk by adding
one disk.

RAID 0

RAID 5

1 or more

3 or more

Yes

At least one disk
needs to be
added for
distributed parity
data.

RAID 0

RAID 6

1 or more

4 or more

Yes

At least two disks
need to be added
for dual
distributed parity
data.

RAID 1

RAID 0

2

2 or more

Yes

Removes
redundancy while
increasing
capacity.

RAID 1

RAID 5

2

3 or more

Yes

Maintains
redundancy while
doubling capacity.

RAID 1

RAID 6

2

4 or more

Yes

Two disks
required to be
added for
distributed parity
data.

RAID 5

RAID 0

3 or more

3 or more

Yes

Converts to a non-
redundant virtual
disk and reclaims
disk space used
for distributed
parity data.

RAID 5

RAID 5

3 or more

4 or more

Yes

Increases
capacity by
adding disks

RAID 5

RAID 6

3 or more

4 or more

Yes

At least one disk
needs to be
added for dual
distributed parity
data.

RAID 6

RAID 0

4 or more

4 or more

Yes

Converts to a non-
redundant virtual
disk and reclaims

19

Advertising
This manual is related to the following products: