Physical disk issues, Physical disk in failed state, Unable to rebuild a fault tolerant virtual disk – Dell PowerEdge RAID Controller H710 User Manual

Page 79: Fatal error or data corruption reported, Physical disk displayed as blocked

Advertising
background image

Corrective
Action:

The issue occurs
because of any of
the following
causes:

The driver is not native in the operating system.
To resolve the issue, press <F6> to install the RAID device
driver during installation.

The virtual disks are not configured properly.
To resolve the issue, enter the BIOS Configuration Utility
(<Ctrl> <R>) to configure the virtual disks. For procedures to
configure the virtual disks, see the topic

Management

Applications For PERC Cards

.

The controller BIOS is disabled.
To resolve the issue, enter the BIOS Configuration Utility
(<Ctrl> <R>) to enable the BIOS. For information on
configuring virtual disks, see the topic

Management

Applications For PERC Cards

.

Physical Disk Issues

Physical Disk In Failed State

Issue:

One of the physical disks in the disk array is in the failed state.

Corrective
Action:

Update the PERC cards to the latest firmware available on dell.com/support.

Unable to Rebuild A Fault Tolerant Virtual Disk

Issue:

Cannot rebuild a fault tolerant virtual disk. For more information, see the alert log for virtual
disks.

Corrective
Action:

The replacement disk is too small or not compatible with the virtual disk. Replace the failed
disk with a compatible good physical disk with equal or greater capacity.

Fatal Error Or Data Corruption Reported

Issue:

Fatal error(s) or data corruption(s) are reported when accessing virtual disks.

Corrective
Action:

Contact Dell Technical Support.

Physical Disk Displayed As Blocked

Issue:

One or more physical disks is displayed as Blocked and cannot be configured.

Corrective
Action:

Update the PERC cards to the latest firmware available on dell.com/support.

79

Advertising
This manual is related to the following products: