To recover a virtual disk from a degraded state, you must replace the failed physical disk and rebuild it. Once the
rebuilding process is complete, the virtual disk state changes from degraded to optimal. For information on rebuilding
the disk, see the topic

Performing A Manual Rebuild Of An Individual Physical Disk

.

Memory Errors

Memory errors can corrupt cached data, so the controllers are designed to detect and attempt to recover from the
memory errors. Single-bit memory errors can be handled by the controller and do not disrupt normal operation. A
notification is sent if the number of single-bit errors exceeds a threshold value.
Multi-bit errors are more serious as they result in corrupted data and data loss. The following are the actions that occur
in the case of multi-bit errors:

If a multi-bit error occurs while accessing data in the cache when the controller is started with dirty cache, the

controller discards the cache contents. The controller generates a warning message to the system console to

indicate that the cache was discarded and generates an event.

If a multi-bit error occurs at run-time either in code/data or in the cache, the controller stops.

The controller logs an event to the controller’s internal event log and a message during POST is displayed

indicating a multi-bit error has occurred.

NOTE: In case of a multi-bit error, contact Dell Technical Support.

Preserved Cache State

The controller preserves the dirty cache from a virtual disk if the virtual disk becomes offline or is deleted because of
missing physical disks. This preserved dirty cache is called pinned cache and is preserved until you import the virtual
disk or discard the cache.
Use the BIOS Configuration Utility (<Ctrl> <R>) to select whether to import the virtual disk or discard the preserved
cache. In the VD Mgmt menu, select Manage Preserved Cache and follow the steps on the screen.

General Issues

PERC Card Has Yellow Bang In Device Manager

Issue:

The device is displayed in Device Manager but has a yellow bang (exclamation mark).

Corrective
Action:

Reinstall the driver. For more information on reinstalling drivers, see the topic

Driver

Installation

.

PERC Card Not Seen In Device Manager

Issue:

The device does not appear in the Device Manager.

Correction:

Turn off the system and reseat the controller.
For more information see,

Installing The PERC Controller

.