Virtual disk management, Creating virtual disks – Dell PowerEdge RAID Controller H710 User Manual

Page 41

Advertising
background image

Parameter

Description
No-Read-Ahead specifies that the controller does not use read ahead for the current

virtual disk.
Adaptive specifies that the controller begins using Read-Ahead if the two most recent

disk accesses occurred in sequential sectors. If all read requests are random, the

algorithm reverts to No-Read-Ahead; however, all requests are still evaluated for

possible sequential operation.

Virtual Disk Management

Creating Virtual Disks

NOTE: Combining SAS and SATA disk drives within a virtual disk is not supported. Also, combining disk drives and
SSDs within a virtual disk is not supported.

NOTE: To create secured virtual disks, see the topic

Security Key And RAID Management

.

Perform the following steps to create a virtual disk:

1.

During host system bootup, press <Ctrl><R> after the BIOS screen is displayed.
The Virtual Disk Management screen is displayed. If there is more than one controller, the main menu screen is
displayed. Select a controller, and press <Enter>. The Virtual Disk Management screen is displayed for the selected
controller.

2.

Use the arrow keys to highlight Controller # or Disk Group #.

3.

Press <F2>.
The list of available actions is displayed.

4.

Select Create New VD and press <Enter>.
The Create New VD screen is displayed. The cursor is on the RAID Levels option. When adding a virtual disk to a
Disk Group, the Add VD in Disk Group screen is displayed. Skip to step 11 to change the basic settings of the virtual
disk.

5.

Press <Enter> to display the possible RAID levels, based on the physical disks available.

6.

Press the down-arrow key to select a RAID level and press <Enter>.

7.

When creating a spanned virtual disk (RAID 10, 50 or 60), enter the number of physical disks per span in the PD per

Span field and press <Enter>.

NOTE: Creating a 22 physical disk RAID 10 VD is possible by selecting RAID 10 and populating the PD per Span
field with 22.

8.

Press <Tab> to move the cursor to the list of physical disks.

9.

Use the arrow key to highlight a physical disk and press the spacebar, <Alt> , or <Enter> to select the disk.

10. Select additional disks, if required.

NOTE: (PERC H310) Only RAID Capable physical disks are eligible to be included in a Virtual Disk. To convert
physical disks to RAID Capable, see the topic

Converting Physical Disk To RAID Capable For PERC H310

.

11. Press <Tab> to move the cursor to the Basic Settings box.
12. Set the virtual disk size in the VD Size field.

The virtual disk size is displayed in GB format.

13. Press <Tab> to access the VD Name field, and type a virtual disk name.
14. Press <Tab> to move the cursor to Advanced Settings.

41