Lists cau – Cisco 3550 User Manual

Page 53

Advertising
background image

3-3

Catalyst 3550 Switch Hardware Installation Guide

OL-6155-01

Chapter 3 Troubleshooting

Diagnosing Problems

Table 3-1

describes some common problems and their solutions.

Table 3-1

Common Problems and Solutions

Problem

Solution

System LED is not on, and the
switch does not run POST.

•

Check that the power cable is connected to the switch and to a
known power source.

•

Test the power cable on another switch.

•

Connect a working power cable from another switch.

System LED is amber.

•

An internal fan fault is detected. Either check the switch itself,
or use the show env user EXEC command to check for a failed
fan.

•

The switch might be overheating. Use the show env user EXEC
command to check for an overtemperature condition. If there is
an overtemperature condition:

–

Place the switch in an environment that meets the
environmental requirements given in

Appendix A,

“Technical Specifications.”

–

Make sure that the fan intake and exhaust areas are clear.

•

A fatal POST error is detected. See the

“Understanding POST

Results” section on page 3-1

.

Advertising