Catalyst 3550 Multilayer Switch Hardware Installation Guide

OL-6155-01

Appendix D Configuring the Switch with the CLI-Based Setup Program

Accessing the CLI Through the Console Port

Figure D-1

Connecting a Switch Console Port to a PC

Starting the Terminal-Emulation Software

Before you power on the switch, start the terminal emulation session so that you can see the output
display from the power-on self-test (POST).

The terminal-emulation software—frequently a PC application such as Hyperterminal or
ProcommPlus—makes communication between the switch and your PC or terminal possible.

Follow these steps to start a terminal-emulation session:

Step 1

Start the terminal-emulation program if you are using a PC or terminal.

Step 2

Configure the baud rate and character format of the PC or terminal to match these console port default
characteristics:

9600 baud

8 data bits

1 stop bit

No parity

None (flow control)

1

Catalyst 3550 switch

3

RJ-45-to-DB-9 adapter cable

2

Power cord

100-240V~

5-3A

50/60H

z

DC OUTPUT 1

CONSOLE

101825

1

2

3