Chapter 4 Troubleshooting the Installation

Troubleshooting Overview

4-4

Cisco XR 12410 and Cisco XR 12810 Router Installation Guide

OL-17441-01

Identifying Startup Issues

Table 4-1

shows the contents of the alphanumeric displays on the RP and the line

cards, as well as the normal LED states on the alarm card, the power entry
modules (AC or DC), and the blower module after a successful system startup.

Table 4-1

Alphanumeric Displays and LEDs at System Startup

Component

Type of Indicator

Display Contents/LED Status and Meaning

RP

Alphanumeric
display

Top row: MSTR

Bottom row: PRP

The RP is enabled and recognized by the system; a valid
Cisco software image is running.

Line Cards

Alphanumeric
display

Top row: IOS XR

Bottom row: RUN

The line card is enabled and ready for use.

Alarm Display

Detected alarm
severity

MBUS (Alarm A and
Alarm B cards)

CSC 0 and 1

SFC 0, 1, 2, 3, and 4

Critical: Off

Major: Off

Minor: Off


Enabled: On

Fail: Off

Enabled: On

Fail: Off

Enabled: On

Fail: Off

AC Power
Supplies

Power status

Pwr OK: On

Fault: Off

Temp: Off

Ilim: Off

The correct power module voltages are present and no faults
have been detected.

Advertising