CDP-338ESD/608ESD

SECTION 3

DIAGRAMS

REFERENCE

Focus/Tracking Gain Adjustments

A frequency responce analyzer is necessary in order to perform

this adjustment exactly.

However, this gain has a margin, so even if it is slightly off,

there is no problem. Therefore, do not perform this adjustment.

Focus/tracking gain determines the pick-up follow up (vertical

and horizontal) relative to mechanical noise and shock when the
2-axis device operate.

However, as these reciprocate, the adjustment is at the point

where both are satisfied.

• When gain is raised, the noise when the 2-axis device operates

increases.

• When gain is lowered, mechanical shock and skipping occurs

more easily.

• When gain adjustment is off, the symptoms below appear.

Gain

Symptoms

Focus

Tracking

• The time until music

starts becomes longer
for ■ ^ O or automatic
selection. (Kl<l, [>t>l but­
tons pressed.) (Normally
tapes about 1 seconds.)

low

low or high

• Music does not start and

disc continues to rotate
for ■ -> > or automatic
selection.

(KKl, OCH buttons pressed.)

-

low

• Disc table opens shortly

after ■->•[>.

low or high

-

• Sound is interrupted

during PLAY or time
counter display stops
progressing.

low

• More noise during 2-axis

device operation.

high

high

The following is a simple adjustment method.

—Primary Adjustment-

Note

: Since exact adjustment cannot be performed, remember

the positions of the controls before performing the adjust­
ment. If the position after the primary adjustment are only
a little different, return the controls to the original posi­
tion.

Procedure :

oscilloscope

(DC range)

main board

TP (FEO)

O

O

TP (TEO) o^- -

I

,

------------L

0 +

o-

1. Keep the set horizontal.

(

If the set is not horizontal, this adjustment

\

cannot be performed due to the gravity against the
2-axis device.

/

2. Insert disc (YEDS-18 : Fifth Selection) and press 0 button.
3. Connect oscilloscope to main board TP (FEO).
4. Adjust RV103 so that the waveform is as shown in the figure

below, (focus gain adjustment)

5. Connect oscilloscope to main board TP (TEO).
6. Adjust RV102 so that the waveform is as shown in the figure

below, (tracking gain adjustment)

VOLT/DIV:

IV

TIME/DIV: 2mS

3-1. CIRCUIT BOARDS LOCATION

POWER BOARD

Incorrect Examples (fundamental wave appears)

low tracking gain

WA

VOLT/DIV:

lOOmV

TIME/DIV: 2ms

100 mV

VOLT/DIV:

IV

TIME/DIV: 2mS

-OV

' Incorrent Examples (DC level changes more than on adjusted

waveform)

_______

low focus gain

VOLT/DIV:

lOOmV

TIME/DIV: 2mS

high tracking gain

(higher fundamental wave than for low gain)

VOLT/DIV:

IV

TIME/DIV : 2mS

V *V '/

-250mV

high focus gain

OV

VOLT/DIV:

lOOmV

TIME/DIV: 2mS

Adjustment Location : main board

TEO, RV102