Adjustment step 1, Adjust the up and down travel limits, Warning – Craftsman 139.53910 User Manual

Page 27: Caution

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

ADJUSTMENT STEP 1

Adjust the UP and DOWN Travel

Limits

Limit adjustment settings regulate the points at which
the door wiil stop when moving up or down.

To operate the opener, press the Door Controi push

bar. Run the opener through a complete travel cycie.

• Does the door open and close completely?

• Does the door stay closed and not reverse

unintentionally when fully closed?

If your door passes both of these tests, no limit

adjustments are necessary unless the reversing test
fails (Adjustment Step 3, page 29).

Adjustment procedures are outlined below. Read the
procedures carefully before proceeding to
Adjustment Step 2. Use a screwdriver to make limit
adjustments. Run the opener through a complete

travel cycle after each adjustment.

NO TE:

Repeated operation of the opener during

adjustment procedures may cause the motor to

overheat and shut off. Simpiy wait 15 minutes and
try again.

NO TE:

If anything interferes with the door’s upward

travel, it will stop. If anything interferes with the
door’s downward travel (including binding or
unbalanced doors), it will reverse.

HOW AND WHEN TO ADJUST THE LIMITS

If the door does not open com pletely but opens

at least five feet (1.5 m ):

increase up travel. Turn the UP limit adjustment
screw clockwise. One turn equals 2" (5 cm) of

travel.

NO TE:

To prevent the trolley from hitting the cover

protection bolt, keep a minimum distance of 2-4"

(5 cm -10 cm) between the trolley and the bolt.

• If door does not open at least 5 feet (1.5 m ):

Adjust the UP (open) force as explained in
Adjustment Step 2.

If the door does not close com pletely:

increase down travel. Turn the down limit
adjustment screw counterclockwise. One turn
equals 2" (5 cm) of travel,

if door still won't close completely and the trolley
bumps Into the pulley bracket (page 4), try
lengthening the door arm (page 25) and

decreasing the down limit.

If the opener reverses in fully closed position:

Decrease down travel. Turn the down limit
adjustment screw clockwise. One turn equals 2"
(5 cm) of travel.

A

WARNING

Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLY INJURED or KILLED by a Closing garage
door.
• Incorrect adjustment of garage door travel limits will

interfere with proper operation of safety reversal
system.

• If one control (force or travel limits) is adjusted, the

other control may also need adjustment.

• After ANY adjustments are made, the safety reversal

system MUST be tested. Door MUST reverse on

contact with 1-1/2" high (3.8 cm) object (or 2x4 laid
flat) on floor.

CAUTION

To prevent damage to vehicles, be sure fully open door
provides adequate clearance.

Cover Protection Bolt

If the door reverses w hen closing and there is

no visible interference to travel cycle:

If the opener lights are flashing, the Safety

Reversing Sensors are either not installed,
misaligned, or obstructed. See Troubleshooting,
page 22.

Test the door for binding: Puli the emergency

release handle. Manually open and close the door.

If the door is binding or unbalanced, call for a

trained door systems technician. If the door is
balanced and not binding, adjust the DOWN
(close) force. See Adjustment Step 2.

27

Advertising