Diagnostics mode – Salter Brecknell 7620U User Manual

Page 12

Advertising
background image

Model 7620U Bench Scale User’s Manual

12

Diagnostics Mode

Diagnostic (DIAG) Mode

The Diagnostic (DIAG) mode menu lets you test
specific areas of the scale’s function.

These areas are:

Display (DISPLAY) – Shows the version and
revision of the software, followed by a display
segment test.

RAM (RA) – Performs a nondestructive test of
RAM in the processor. Displays “PASS” or
“FAIL.”

ROM (RO) – Performs a checksum of all loca-
tions in ROM in the processor. Displays “PASS”
or “FAIL.”

Input/Output (I-O) – Data is output by the scale
and through the use of a loopback connector the
data is immediately read back into the receive
channel and verified against what was sent.
“PASS” or “FAIL” is displayed. Requires a
jumper (short) between transmit and receive data
lines.

Division, test w/AZT (DIV-A) – Weight data is
normalized to 1,000,000 counts of displayed
resolution. AZT is enabled (Auto Zero Tracking).

Division, test w/o / AZT (DIV-N) – Weight data
is normalized to 1,000,000 counts of displayed
resolution. AZT is disabled.

Raw Counts (RA CNTS) – Non-normalized QDT
cell data (no zero tracking).