Salter Brecknell 7620U User Manual

Page 9

Advertising
background image

Model 7620U Bench Scale User’s Manual

9

Operational Controls

Remote Display

Accessing the

Menu Mode

Accessing the

Gravity Setting Mode

ZERO Key – The ZERO key will zero the scale
if weight is stable, functions as the NO or
SCROLL key in the Menu mode, and as the
INCREASE key in the Gravity mode.

F1 Key – The F1 key can be used to recall the
scale configuration information during the
initial power-up test sequence. This key also
functions as YES or ACCEPT in the Menu
mode, and as the DECREASE key in the
Gravity mode.

All NCI 7620 bench scales can have an
optional remote display (shown above with no
keyboard function). If a remote display with
keyboard is used, then Switch 3 (shown in
Figure 1) determines which display keyboard
is functional.

Switch 3 Settings
Closed= internal display keys operational
Open = external display keys operational

The 7620 family powers up in normal weighing
mode ready for weighing operations. You can
access the Menu mode by setting Switch 1
shown in Figure 1 to the OPEN or Menu mode
position.

Access the GRAVITY setting mode by setting
Switch 2 shown in Figure 1 to the OPEN or
GRAVITY mode position.

Advertising