103104 Page 9

DETEX ED UNITS MAY BE OPERATED FROM A 24 V AC OR DC

SOURCE OR WITH A DETEX POWER SUPPLY

(NOTE: FIRE RATED DEVICES MUST USE 80-800-X POWER SUPPLY)

(Optional)

WIRES FROM EX SWITCH

RED (+)

POWER CABLE FROM ED MODULE

(CONNECT TO POWER SUPPLY)

BLACK(-)

ED CONFIGURATION

CONNECTIONS FOR THE ED MODEL

For transformer operation, the ED device can use a transformer or power supply. Use Detex part number

PP-5152-2 transformer or approved 24 volt Class 2 equivalent rated at 40 VA or higher. An appropriate switch

must be used to control the power to the device. See Figure 1 on page 10 for a typical installation. Detex power

supply 80-800 may also be used. See Figure 2 on page 10 for a typical installation. Fire rated doors must use the

80-800 power supply. This is because transformers cannot be controlled by the building's fire system. Connections

to the building's fire system are described in the power supply instructions.

RETRACTING THE LATCH

The ED model is electrically dogged, but has no mechanism to retract the latch. Once the switch is

activated/closed and power is supplied to the device, press the pushpad to open the door. As the pushpad

reaches the proper amount of travel, it will automatically latch into place. The pushpad will be held in this position

as long as the control switch is maintained(closed).

HOLDING THE LATCH RETRACTED

ED model holds the latch retracted as long as the control switch is maintained(closed).

RELEASING THE LATCH

ED is an electronically dogged latch. Opening the control switch (or contacts) causes the latching mechanism to

release the lock.

YELLOW (OPEN)

GREY (CLOSED)

BROWN (COMMON)