Detex AO19-2 Pull User Manual

Page 4

Advertising
background image

Installation

104853 Page 4

SECURE HANGER WITH SCREWS

5/8”

1-1/16”

Once they are seated, pull down until unit is completely flush and screws can be replaced in top

corners.

Lift the operator and lower onto the webs of the hanger plate bracket. Be sure both top and

bottom are engaged.

Replace

Screw

here

Replace

Screw

here

Hanger Plate Location for Twin Pull Unit

The hanger plate should be located 5/8" from the outside edge of the hinge jamb, (typical 1 3/4”

frame face) level and 1-1/16” above bottom of the door frame. Bar clamp the hanger plate.

Using hanger plate, mark and drill holes into header frame, solid wall or wall stud. Fasten using

appropriate type and size screws (Detex recommends using flat head type).

Note: Drilling debris accumulated in hanger groove tracks can prevent the operator from seating

uniformly when mounting. Remove debris with thin brush. Masking tape can also be used to

prevent debris from collecting in groove.