Detex MS-2049F User Manual

Detex Safety

Advertising
background image

INS-2049F April 20, 2007

INSTALLATION INSTRUCTIONS FOR MAGNETIC SWITCH MS-2049F

Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130 (830)629-2900 1-800-729-3839 FAX (830)620-6711

E-Mail: [email protected] Internet: www.detex.com

ELECTRICAL

SPECIFICATIONS

SWITCH (SPDT)

MAXIMUM CONTACT RATING;

500 mA at 24V

BLK COM

RED OPEN

WHT CLOSED

WHT

RED

BLK

SHOWN DOOR SECURE

MS-2049F POSITION

The preferred position of the mag-

netic switch is the top of the door,

centered approximately 6” from the

edge of the door, as shown.

Contacts should be installed so that

the door cannot be opened more than

2 inches without causing an alarm

condition.

1 - 1/16”

3 - 1/2” CENTERED ON PLATE

SWITCH MS-2058
SWITCH - PLATE

1.25X4.875X.075

HOLE CENTERS SAME

AS MAGNET PLATE
SCREWS FOR SWITCH

AND MAGNET ARE

#8-32

P/N MS-2053
MAGNET MS-2057

MAGNET PLATE

1.25X4.875X.075

6”

TO CENTER OF MAGNET

DOOR

1-1/4” MIN

NOTE: DOOR AND FRAME PREPARATION

PER ANSI A115.2

1 - 1/2”

DIMENSIONS:

A = 3-1/2” MIN B = 4-1/8” C = 4-15/16” MIN

NOTE: The dimensions given in the illustration apply to the door and

frame preparation for top of door or latch side installation.

Special screws, #8-32 x 1/4” flat head are provided.

Special attention must be given to the alignment of the switch and

magnet, especially longitudinal. The maximum allowable misalign-

ment in any direction is 1/8”.

DETEX INS2049F

Advertising