Detex MS-2049SI User Manual

Detex Safety

Advertising
background image

Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130 (830)629-2900 1-800-729-3839 FAX (830)620-6711

E-Mail: [email protected] Internet: www.detex.com

INS-2049SI April 20, 2007

INSTALLATION INSTRUCTIONS FOR MAGNETIC SWITCH MS-2049SI

MS-2049SI POSITION

The preferred position of the mag-

netic switch is the top of the door,

centered approximately 6" from the

edge of the door, as shown.

Contacts should be installed so that

the door cannot be opened more than

2 inches without causing an alarm

condition.

ELECTRICAL SPECIFICA-

TIONS

SWITCH (SPDT)

MAXIMUM CONTACT RATING;

500 mA at 24V

SHOWN DOOR SECURE

DETEX INS2049SI PAGE 1

Use the template to mark the hole

locations on the door and frame.

The MS-2049SI should be located as

shown in column 1.

Mark the hole centers and drill the

holes as required on the template.

Install the bracket on the door with

three screws, #10 x 1", flat head

thread-forming.

Position the magnet on the bracket

and slip the cover up into position.

Fasten these parts together with two

screws, #8-32 x 3/4", as shown.

Install the bracket on the door frame

with two #10 x 1" flat-head thread-

forming screws.

Press the bushing, MS-2072 into the

bracket. Thread the switch wires

through the bushing and position the

switch on the bracket. Position the

cover on the bracket and fasten the

cover and switch to the bracket with

two #8-32 x 3/4" flat-head screws.

Connect the switch wires to the wires

from the monitoring device.

BLK COM

RED OPEN

WHT CLOSED

WHT

RED

BLK

PROBLEMS?

Contact Customer Service at

1-800-729-3839

Advertising