EFCO S5500 Advanced User Manual
Page 33

EFCO CORPORATION 6/2012 PART NO. Y557
33
Series 5500 Advanced & Alternate Installation Instructions
Section V: Vertical Splice Joints
STEP #8 INSTALL INTERIOR GASKETS, GLAZING, AND EXTERIOR GASKETS
A. Install the interior gaskets allowing them to span the mullion splice joint.
B. Set the glazing into the opening as previously instructed.
C. Apply the exterior vertical drive-in wedge gaskets into the vertical mullions as
shown in Section VI of the Standard Installation Instructions.
D. Apply the horizontal pressure covers and horizontal exterior drive-in wedge
gaskets at the top and bottom of the lite as shown in the Standard Installation
Instructions.
GLAZING INFILL
INTERIOR GASKETS
(Runs continuously
through splice joint)
EXTERIOR GASKETS
(Runs continuously
through splice joint)
GLAZING ADAPTERS
(When required)