Series 5500 Advanced & Alternate Installation Instructions

Section VIII: Captured Glazing Adaptor Installation

STEP #1 INSTALL GLAZING ADAPTERS

A. Prior to installing the glazing adapters, seal the full length of the gasket raceway

with sealant.

B. Snap the glazing adapters in place into the sealant starting with the verticals.

Allow at least 1/8” clearance from the bottom of the glazing adapters to the top of

the joint plugs to allow for weepage.

C. Apply sealant to the ends of the horizontal adapters prior to setting them into

position. Snap the horizontal adapters in place between the vertical adapters. Seal

the face of the adaptor intersections with sealant. Tool all sealant joints and

remove all excess sealant.

Continuously seal the

gasket raceway with

sealant prior to
installing the adapters.

GLAZING ADAPTERS

NOTE: The vertical adapters

will need clearance above

the joint plugs, free from

sealant for weepage.

Glazing adapter cut formula:

Vertical = D.L.O. + 1”
Horizontal = D.L.O. – 1/16”