Header installation with offset pivots, Closer preparation and, Con’t) – EFCO Dorma RTS 88 User Manual
Page 9

BAB 7/01
PAGE 7
B. OFFSET PIVOTS
2. 1 3/4" OR 2" HEADER/T’BAR INSTALLATION STEPS
SECTION II HEADER/TRANSOM BAR
INSTALLATION
(CON’T)
STEP B.
SPACER {F045}
#10-32X5/8"
PL-FH-MS 18-8
{M130}
STEP A.
ANGLE CLIP {FT16}
STEP C.
#8-32X5/8"
PL-PH-SMS
NOTE:
FOR SINGLE DOORS AT LOCK
JAMB USE K120 SHEAR BLOCK
WITH 2" HDR/T-BAR.
A.
ATTACH ANGLE CLIP {FT16} TO THE HEADER/T’BAR WITH TWO #10-32X5/8’
FH-MS.
B.
APPLICATIONS WITH A 2" HEADER/T’BAR:
ONE SPACER BLOCK {F045} MUST BE USED BETWEEN THE ANGLE CLIP {FT16} AND
THE HEADER/T’BAR. USE TWO #10-32X5/8" FH-MS TO FASTEN THE ASSEMBLY INTO
PLACE.
C.
COAT THE ENDS OF THE HEADER/T’BAR WITH BUTYL TYPE SEALANT AND
FASTEN THE ANGLE CLIP(S) {FT16} AND THE HEADER/T’BAR TO THE HINGE/PIVOT
JAMB(S) WITH THREE #8-32X5/8" PL-PH-SMS.
D.
AT SINGLE DOORS:
LOCATE THE HEADER/T’BAR ON THE SHEAR BLOCK AT THE LOCK JAMB AND
FASTEN IN PLACE WITH THE SUPPLIED SCREWS.