2.

Drive the Model 7605 with sufficient current to produce a magnetic flux
density 10 dB greater than the applicable limit in MIL-STD-46ID [9], but
do not exceed 15 A; for example, 183 dB(pT). The following chart
shows the Model 7605 coil current at the RS101 limits.

3.

Scan the frequency range from 30 Hz to 100 kHz. The scan rate may
be three times faster than the rates specified in Table III of
MIL-STD-462D.

In the 30 Hz to 100 kHz range the specified rates are 0.02f

0

per second for analog scans and 0.01f

0

steps (1% steps) for stepped

scans; so for these frequency selecting scans, the scan rates can be
0.06f

0

per second for analog scans and 3% steps for stepped scans.

32

|

MIL-STD-462D Method RS101 Testing

Advertising