Doors

Door Operation for Type G

This door is most often installed on large chambers for large equipment access.

Operating and maintenance instructions differ quite significantly from the

standard swing doors; therefore, individual operation and maintenance manuals

are issued with each door fitted to a chamber.

Adjusting RCM 1 Hinges

Adjustment is the same for left and right hinges. All hinges must be aligned

together.

U

P

-

AND

-D

OWN

A

DJUSTMENT

1.

Open the door.

2.

Place a hex key in the top of the hinge pin.

3.

Turn the hinge pin clockwise to move the door leaf up; turn the hinge

pin counterclockwise to move the door down. Approximately three to

four turns are typically required to set the correct spacing between

door and the jamb; for example, 1/8 in (3 mm) to 5/32 in (4 mm).

4.

Close the door.

5.

Repeat as required.

S

IDE

-

TO

-S

IDE

A

DJUSTMENT

1.

Adjust each hinge as required to move either the top or bottom of the

door leaf.

2.

Close the door. Do not loosen the dome head nuts on the frame side of

the hinge.

3.

Loosen the M5 x 10 mm grub screw on the side of the hinge fitted to

the door leaf.

4.

Loosen the three dome nuts on the hinge (3/8-in diameter).

5.

Move the door leaf to set the correct spacing between door and the

jamb. Tighten dome nuts and torque to 12 ft lb.

Advertising