Good Shielding Practices

| 7

1.0 Good Shielding Practices

To retain the RF shielding integrity of the chamber, follow these good shielding

practices:

Periodically clean and lubricate doors.

When mounting screw-retaining items within the enclosure, do not

penetrate through both shields of a modular panel system. Screws

must not penetrate any portion of the screen system.

Do not use framing screws to fasten items within the enclosure.

When a hole is bored for a new penetration, remove all burrs. Clean

the perimeter of the hole and the penetration with a cleaning agent

before installing the new penetration.

Nothing must penetrate the enclosure wall, floor, or ceiling without use

of a proper ETS-Lindgren designated penetration.

Bolts fitted to the modular and pan-type rooms must be fitted to

correctly-sized holes, correctly de-burred, and cleaned.

Use flat washers on both sides of the shield penetration.