Command Set and Error Codes
Following are the general commands and error codes for the EMCenter. For
device-specific commands, see the separate manual for each card.
C
OMMAND
S
ET
Command Message
Description
*IDN?
Request the identification of the EMCenter
Response: ETS-Lindgren EMCenter version x.x.xx
STATUS?
Request the status of the EMCenter; reply is
device-specific
LOCAL
Return to local mode
REBOOT SYSTEM
Reboot the EMCenter
E
RROR
C
ODES
Error Code
Description
ERROR 1
Internal buffer overflow
ERROR 2
Command too long
ERROR 3
Invalid command
ERROR 4
Command too short
ERROR 5
Invalid parameter
ERROR 6
Parameter too high
ERROR 7
Parameter too low
ERROR 8
Hardware failure
ERROR 9
Reserved
ERROR 10
Reserved
ERROR 20
Unknown device type
ERROR 21
Unknown device number