background image

Principles of Operation

MODEL 94456 CURRENT PROBES

2

© EMC TEST SYSTEMS, L.P. – MARCH 2002

REV B – PN 399265

PRINCIPLES OF OPERATION

The RF Current Probe, Model 94456 is an inserted-primary

type of radio frequency current transformer. When the

probe is clamped over the conductor or cable in which

current is to be measured, the conductor forms the primary

winding. The clamp-on feature of this probe enables easy

placement around any conductor or cable.

CIRCUIT

The circuit is that of a radio frequency transformer as

illustrated below:

O u t p u t t o C o a x i a l C a b l e
5 0 O h m s I m p e d a n c e

S e c o n d a r y W i n d i n g

E l e c t r o s t a t i c
S h i e l d ( C a s e )

N o i s e C u r r e n t s

P r i m a r y ( T e s t S a m p l e L e a d )

Figure 1. Basic RF Transformer

Since the current probe is intended for “clamp on”

operation, the primary shown in Figure 1 is actually the

electrical conductor in which interference currents are to be

measured. This primary is considered as one turn since it is

assumed that the noise currents flow through the conductor

and return to the source via a “ground” conductor such as a

frame, common ground plane, or earth. On some current

probe models the secondary output terminals are resistively

Archived 6/1/10