59

sToRAge

Always clean the appliance before storing (see ‘Care and cleaning’). Ensure to store the

appliance where it is clean, dry and safe from frost, direct sunlight and inadmissible strain

(mechanical or electric shock, heat, moisture) and where it is out of reach of young children.

Place the appliance on a clean and stable surface, where it can not fall. Do not place any

hard or heavy objects on the appliance. To avoid touching the blade unintentionally or to loose

any accessories, it is good advice to store the blender completely and properly assembled.

TRouBLe shooTing

The Design Blender Advanced Pro is reliable and robust and handling it with care it will oper-

ate properly. For the case that problems show up you can solve the problems on your own

using the trouble shooting guide.

wARning:

Only use the appliance for the intended use. For attendance and repair take

the appliance to an authorised service centre.

Problem

Solution

Motor doesn’t start or blade doesn’t

rotate

Check that the power plug is securely inserted into the power outlet Check that the blade assembly

housing is correctly attached to the base of the blender jug and that the jug is securely locked into

position. Check that the Power button flashes red and the selected function is illuminated in blue.

Be sure to press only one function button at a time.

The motor stucks or slows down

Use the Ice Auto Pulse function to pre-cut the food with short bursts of power. If necessary

(because the blender jug is overloaded) pour out part of the content of the blender jug. Chop hard

ingredients such as nuts or chocolate before putting them into the blender jug.

The motor stops or you can not turn the

motor on again

Turn the appliance

›OFF‹, if the motor stops all of a sudden or stalls during operation to avoid

overheating. Go through following checking list:

– The unit automatically shuts off after operating for 2 minutes (Blend function) and after 1

minute (Smoothie and Ice Auto Pulse function) to avoid overheating. If you want to operate

again, wait shortly continue to operate.

– Take the blender jug off the motorblock and clear out firmly bounded food that blocks the blade

using a spoon. Do not use force to avoid damaging the blade.

– Chop hard ingredients such as nuts or chocolate before putting them into the blender jug. If

necessary (because the blender jug is overloaded) pour out part of the content of the blender

jug and try to restart the motor using the Ice Auto Pulse function to start with.

ATTENTION: Do not try to mix ingredients of very hard consistency or ingredients which are

too big in size to avoid overloading the motor. Do not overfill the blender jug. Process very

hard food in more then one go. The mixer is not intended for chopping nuts with shell, bones

or simular hard ingredients.

The bottom of the blender jug untight-

ens during operation; liquid leaks.

Turn the appliance

›OFF‹ and pull the plug out of the power outlet. Empty the blender jug. Clean

and dry the motorblock. If any ingress of moisture into the motorblock or through the louvre take

the appliance for technical maintenance and repair to an authorised specialised reparation shop.
Ensure the blender jug is properly assembled.
Tip: Before filling liquid into the blender jug check if the blender jug is leak-proof by filling it

with water. Check the sealing ring. If necessary replace damaged units by original spare parts

of the manufacturer.