IPMI Firmware

CP6003-SA/RA/RC

Page 26

ID 1045-5656, Rev. 2.0

P R E L I M I N A R Y

14h /
NNN:Health Error

Platform Alert (24h) /
“digital” Discrete (03h)

0000h / 0000h /
0003h

Aggregates states (power,
temperatures etc.).
Visualization by the Health
LED (LED I1, red).

N

15h /
NNN:CPU 0 Status

Processor (07h) /
Sensor-specific (6Fh)

0463h / 0400h /
04E3h

CPU status: “Processor
Throttled, THERMTRIP or
CAT error”

Y

/ 0403h

16h /
NNN:POST Value

POST value OEM (C6h) /
Sensor-specific (6Fh)

4000h / 0000h /
40FFh

POST code value (port 80h)

N

17h /
NNN:LanFrontA_Lk

LAN (27h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

LAN link status –
Front Eth. port A (lower)

N

18h /
NNN:LanFrontB_Lk

LAN (27h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

LAN link status –
Front Eth. port B (upper)

N

19h /
NNN:LanRearC_Lk

LAN (27h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

LAN link status –
Rear Eth. port C

N

1Ah /
NNN:LanRearD_Lk

LAN (27h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

LAN link status –
Rear Eth. port D

N

1Bh /
NNN:FWH0 BootErr

Boot error (1Eh) /
Sensor-specific (6Fh)

0008h / 0008h /
0008h

Boot error on standard SPI
boot flash

Y

/ 0008h

1Ch /
NNN:FWH1 BootErr

Boot error (1Eh) /
Sensor-specific (6Fh)

0008h / 0008h /
0008h

Boot error on recovery SPI
boot flash

Y

/ 0008h

1Dh /
NNN:XMC present

Entity Presence (25h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

Presence of XMC board

N

1Eh /
NNN:FRU Agent

OEM FRU Agent (C5h) /
Discrete (0Ah)

0140h / 0000h /
0147h

FRU initialization agent
state

Y

/ 0140h

1Fh /
NNN:IPMC Storage

Management Subsystem
Health (28h) /
Sensor-specific (6Fh)

0002h / 0000h /
0003h

IPMI controller storage
access error

Y

/ 0002h

20h /
NNN:IpmC Reboot

Platform Alert (24h) /
“digital” Discrete (03h)

0002h / 0000h /
0003h

2 = IPMI controller is (re-
)booting

N

21h /
NNN:Ver change

Firmware version changed
(2Bh) /
Sensor-specific (6Fh)

0002h / 0000h /
0002h

Firmware version changed,
update sensor data record
repository

N

22h /
NNN:SEL State

Event Logging Disabled (10h)
/ Sensor-specific (6Fh)

003Ch / 0000h /
003Ch

State of event logging

N

23h /
NNN:IPMI Info-1

OEM Firmware Info 1 (C0h) /
OEM (70h)

0003h / 0000h /
7FFFh

For internal use only

N

24h /
NNN:IPMI Info-2

OEM Firmware Info 2 (C0h) /
OEM (71h)

0003h / 0000h /
7FFFh

For internal use only

N

25h /
NNN:IniAgent Err

Initialization Agent (C2h) /
“digital” Discrete (03h)

0002h / 0000h /
0003h

Initialization agent error
status. Used on BMC only.
1 = error free

Y

/ 0002h

26h /
NNN:Board Rev

OEM Board Revision (CEh)/
Sensor-specific (6Fh)

0000h / 0000h /
7FFFh

Board revision information

N

Table 9:

Sensor List (Continued)

SENSOR NUMBER /

ID STRING

SENSOR TYPE (CODE) /

EVENT/READING TYPE

(CODE)

Ass. Mask /

Deass. Mask /

Reading Mask

DESCRIPTION

LED I1on