2 com 0 sub-menu – Kontron AT8060 User Manual

Page 103

Advertising
background image

Software Setup

88

AT8060

www.kontron.com

5.1.4.10.2

COM 0 sub-menu

Feature

Option

Description

Help text

COM0

Subtitle

Console Redirection

Settings

Subtitle

Terminal Type

VT100, VT100+, VT-

UTF8, ANSI

Emulation: ANSI:

Extended ASCII char set.

VT100: ASCII char set.

VT100+: Extends VT100

to support color,

function keys, etc. VT-

UTF8: Uses UTF8

encoding to map

Unicode chars onto 1 or

more bytes.

Bits per second

9600, 19200, 38400,

57600, 115200

Selects serial port

transmission speed. The

speed must be matched

on the other side. Long

or noisy lines may

require lower speeds.

Data Bits

7, 8

Data Bits

Parity

None, Even, Odd,

Mark, Space

A parity bit can be sent

with the data bits to

detect some

transmission errors.

Even: parity bit is 0 if the

num of 1's in the data

bits is even. Odd: parity

bit is 0 if num of 1's in

the data bits is odd.

Mark: parity bit is always

1. Space: Parity bit is

always 0. Mark and

Space Parity do not

allow for error

detection. They can be

used as an additional

data bit.

Stop Bits

1, 2

Stop bits indicate the

end of a serial data

packet. (A start bit

indicates the

beginning). The

standard setting is 1

stop bit. Communication

with slow devices may

require more than 1 stop

bit.