Server Component Installations and Upgrades—NSC2U Server

The IP Network Server NSC2U does not support all SAS hard drives. To see a list of

validated manufacturers and hard drive types, refer to the Tested Hardware and

Operating System List (THOL) at:

http://us.kontron.com/support/

(Search for NSC2U, click on Product Downloads, and

then Compatibility Matrix.)

3.3.1.1

Removing a Hard Drive Tray from the Chassis

1. Remove the front bezel. For instructions, see

Section 3.2.3

,

“Removing the Front

Bezel”

.

2. Select the drive bay where you want to install the drive and remove the drive tray

by pressing the green button to open the lever. (“A”)

Note:

If you will have fewer than six drives installed, drive bay 0 must be used first, then

drive bay 1, and so forth.

3. Pull the drive tray assembly out of the chassis.

3.3.1.2

Attaching a Hard Drive to the Drive Tray

1. If a drive is already installed (that is, if you are replacing the drive), remove it by

unfastening the four screws that attach it to the drive tray. (“A”)

Figure 12.

Removing a Drive Tray from the Chassis

TS000274