Fully redundant power – Cisco 4000 User Manual

Page 16

Advertising
background image

1-16 Cisco 4000 Series Installation Guide

Cisco RPS Support

Fully Redundant Power

The Cisco RPS can provide a fully redundant power source for up to two Cisco 4000 series
routers. You can use a two-to-one cable to connect up to two external devices to the four
DC output power modules on the rear panel of the Cisco RPS, as shown in Figure 1-6. The
two-to-one cable is a Y-shaped cable with two connectors at one end of the cable and one
connector at the other end. Two connectors at one end of the Y-shaped cable connect to two
DC output power modules. The other end of the cable connects to one external device.
When using two-to-one cables, the power source is fully redundant because there are two
AC input modules and two DC output power modules connected to each external device. If
any power module fails, there is a full backup.

Figure 1-6

Fully Redundant Configuration

External devices

150W or less

DC output

AC input

DC

DC

AC

AC

DC

DC

Cisco RPS

NM3998

Advertising