P14 inside glazing guidelines – Oldcastle BuildingEnvelope 3000 XT Series User Manual

Page 14

Advertising
background image

14

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

INSIDE GLAZED GLAZING GUIDELINES

MITER HORIZONTAL GASKET TO

VERTICAL GASKET

DETAIL "A"

DETAIL "B"

1) REMOVE GASKETS FROM ROLL AND ALLOW TO RELAX OVERNIGHT.

ALL GASKETS TO BE CUT D.L.O. + 3/8" PER FOOT.

2) VERTICAL GASKETS RUN THRU, HORIZONTAL GASKETS SHOULD BE

MITERED ON ENDS AS SHOWN IN DETAIL "A"

3) INSTALL EXTERIOR GASKETS PRIOR TO GLAZING. CORNERS OF EXTERIOR GASKETS

TO BE SET IN SEALANT (DTL."B") AND CORNERS SEALED JUST PRIOR TO SETTING

GLASS (DTL."A").

NOTE: CLEAN GASKETS AND SURFACES WITH ISOPOPYL ALCOHOL PRIOR TO

SEALING CORNERS.

4) LOCATE SETTING BLOCKS AT EITHER 1/4 POINTS OR 1/8 POINTS, DEPENDENT ON

SIZE OF GLASS.

5) GLASS IS CUT DAYLIGHT OPENING PLUS 7/8".

6) GLAZE OPENINGS FROM BOTTOM TO TOP. INSTALLING WATER DIVERTERS IN

HORIZONTAL ABOVE, AFTER LITE BELOW IS IN POSITION.

7) WATER DIVERTERS (FG1000-FP-4&5) MUST BE LOCATED ON EACH END OF HORIZONTALS

AND SET IN SEALANT.

8) WHEN INSTALLING GLASS: FIRST, WET TOP OF SETTING BLOCK WITH SOAPY WATER.

ONCE GLASS IS SET IN PLACE, PUSH GLASS AGAINST GASKET AT SETTING BLOCK AREA.

FAILURE TO DO SO MAY CAUSE DIAGONAL CRACKS TOWARDS SETTING BLOCKS DUE TO

GLASS BENDING WHILE INSTALLING GASKET(S) IN CORNERS.

15°

SEAL CORNERS AT

GLAZING TRACK PRIOR

TO SETTING GLASS.

SEAL CORNERS GASKET

RACE AT WATER

DIVERTER.

MAY 2013

S E R I E S 3 0 0 0 X T - I N S T A L L A T I O N M A N U A L

Advertising