ANCHOR AND PERIMETER SEAL

C

C

C

C

NOTE: 5/16" WEEP HOLES REQUIRED

IN FLASHING (E) AT CENTERLINE OF

D.L.O.

APPLY SEALANT ALONG LENGTH OF SILL FLASHING AT

POINT (A).

APPLY FILLET SEAL BETWEEN SILL FLASHING AND FRONT OF SILL (B).

THE QUALITY OF THE INSIDE AND OUTSIDE PERIMETER SEALS (C) MAY

BE IMPROVED BY USING FG-2188 RIGID PVC FILLER. THE PART MAY BE

USED IN FULL LENGTHS OR CUT INTO PIECES. ITS PURPOSE IS TO

PROVIDE SUPPORT FOR THE BACKER ROD REGARDLESS OF JOINT SIZE.

INTERIOR PERIMETER SEAL AT SILL (D) IS OPTIONAL AND FOR COSMETIC

PURPOSES ONLY.

FG3000-FP-58

ANCHOR

FG3000-FP-58 AND FG3000-FP-59

ANCHORS ARE DESIGNED TO

CARRY A MAXIMUM END

REACTION OF 600LBS.

C

C

OPTIONAL MO-678/MO-244

HEAD RECEPTOR

MAXIMUM END REACTION

OF 450 LBS.

C

C

A

D

A

E

B

FG-3506 HEAD WITH FG3000-FP-58 ANCHOR

FG-3510 HEAD WITH FG3000-FP-59 ANCHOR

MAY 2013

S E R I E S 3 0 0 0 X T - I N S T A L L A T I O N M A N U A L