P9 outside glazed center set shrblk assy – Oldcastle BuildingEnvelope 3000 XT Series User Manual

Page 9

Advertising
background image

9

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

OUTSIDE GLAZED SHEAR BLOCK FRAME ASSEMBLY

APPLY SILICONE SEALANT

IN GLAZING REGLET OF

VERTICAL WHERE IT MARRIES

WITH SEALANT APPLIED TO

THE HORIZONTALS

FS-9 (TYP)

#11 (.191)

TAP HOLE

(TYP)

FG-3506

1"

1 3/4"

11/32"

1 1/4"

7/16"

1/4"

2-11/16"

29/32"

TOP OF

HORIZONTAL

NOTE:

*SHEAR BLOCK PACKAGES INCLUDE

FASTENERS AND ROLL PINS

*AC-119-1 (PART#:6295)

*FG3000-FP-60 (pART# 34996)

FS-7

DRILL 1/4" DIA.

HOLE FOR

ROLL PIN

APPLY SILICONE

SEALANT 4" UP

INTERIOR SNAP

JOINT

4"

REFERENCE PAGE 16 FOR USE OF DJ-8 DRILL FIXTURE.

29/32"

#11 (0.191Ø)

TAP HOLE

(TYP.)

FG-3506

#11 (.191)

CLEAR HOLE

FS-6

FG-3509

APPLY SILICONE

SEALANT TO END

OF HORIZONTALS

AS SHOWN

FG-3220

PART# 1122

TYP. #25 (.149)

TAP HOLE

FS-6

FG-3510

FG-3220

PART# 1122

ROLL PIN

11/32"

1 1/4"

FG-3514

MAY 2013

S E R I E S 3 0 0 0 X T - I N S T A L L A T I O N M A N U A L