DOOR FRAME INSTALLATION

NOTES:

1) USE SHEAR BLOCKS AS SHOWN IN FRAME ASSEMBLY SECTION OF THIS MANUAL TO SECURE

HORIZONTALS TO TUBULAR FRAMES.

2) DOOR FRAME IS ANCHORED BY FASTENERS THROUGH THRESHOLD AND DOOR FRAME HEADER.

3) DO NOT FABRICATE STANDARD 2 PIECE POUR & DEBRIDGED FRAME EXTRUSIONS FOR DOOR

FRAMES. IF THERMAL FRAME IS REQUIRED,OPTIONAL THERMAL DOOR FRAME FG-3389 MAY BE

USED IN CONJUNCTION WITH OLDCASTLE BUILDINGENVELOPE THERMAL DOORS.

4) WHEN USING THE CENTER SET SYSTEM, THE TWO-PIECE OR TUBULAR FRAMING OPTION ARE

AVAILABLE AS SHOWN ABOVE. WHEN USING EITHER THE FRONT SET OR BACK SET SYSTEM ONLY

THE TUBULAR OPTION IS AVAILABLE. THE VERTICAL FOR THE FRONT OR BACK SET OPTIONS

IS FG-3287.

FG-3156

FG-3155

FG-2145

LEAVE FRONT OF DOOR JAMB

CLEAR OF SEALANT FOR DRAINAGE

BED SUB-SILL IN

SEALANT AT DOOR JAMB

RUN SEALANT MINIMUM 1"

ABOVE BACK OF SUB-SILL

1"

MAY 2013

S E R I E S 3 0 0 0 X T - I N S T A L L A T I O N M A N U A L