INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Read completely, then follow step by step.

Level gauge
Screwdriver
Electric drill,Hole core drill (

65

mm)

Flaring tool set
Specified torque wrenches: 1.8kgf.m,
4.2kgf.m, 5.5kgf.m, 6.6kgf.m
(different depending on model No.)
Spanner (half union)

Tools needed for installation:

Hexagonal wrench (4mm-6mm)
Gas-leak detector
Vacuum pump
Gauge manifold
Users manual
Thermometer
Multimeter
Pipe cutter
Measuring tape

This illustration is for explanation
purposes only.
Copper lines must be insulated
independently

Use a stud finder to locate studs to
prevent unnecessary damage to the
wall.
Two of the A, B and C directions
should be free from obstructions.

CAUTION

Fig.1

8

9

7

2.3m or more

12cm or m

ore

12cm

or mo

te

15cm or more

1

2

3

C

A

60cm o

r more

6

0

cm

o

r

m

o

re

30cm or

more

Air Fi

lter

Air Fi

lter

Air Outlet

30cm or

more

Wrapping tape(wrap the insulation pipe
with the tape form bottom to top)

B

200cm o

r more

Additional drain pipe

Accessories

( C )

TEMP

AUTO
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

TIMER ON

SLEEP

ON/OFF

TIMER OFF

AIR
DIRECTION

RESET LOCK

SET TEMPERATURE

SWING

LED
DISPLAY

TURBO

There should not be any heat source, inflammable gas or stream near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the restrictions on installation specified in the indoor unit installation drawings are met.
Select a location which is firm enough for installation so that the device is not subjected to
vibrations.
The device should beinstalled at a distance of at least 1m from all other electrical devices and
installations, e.g. TV, radio,computer, etc.
There should not be any direct sunlight. If unavoidable, sunlight prevention should be taken
into consideration.

Indoor unit

Outdoor unit

If an awning is built over the unit to prevent direct sunsight or rain,be careful that heat
radiation from the condenser is not obstructed.
There should not be any animal or plant which could be affected by hot air discharged.
Make sure that there is sufficient space as specified in the installation drawings.
Do not place any obstacles which may cause a short circuit of the discharged air.
Select a location which avoids causing a nuisance to neighbours from noise and air emissions
from device.
Select a location which is sufficiently well ventilated.
Never cover the air inlets and outlets.
The location must be sufficiently firm for installation and the prevention of vibrations.
There must be no risk presented by combustible gas or gas escaping as a result of corrosion.
Avoid a location where there is a high salt content.
Avoid a location which is heavily exposed to dust.
Avoid a location to which the general public have access.

Selecting installation place

1

2

3
4

5

7
8
9
10

6

Installation Plate

Clip Anchor

Self-tapping Screw A ST3.9x25

Seal(For cooling & heating models only)
Drain Joint(For cooling & heating models only

Connecting
pipe
Assembly

Liquid side

Gas side

Remote controller

Air freshening filter(used to install on Air filter)

Self-tapping Screw B ST2.9x10

6.35
9.52

9.52

12.7

16

Parts you must purchase. The
pipe size differ from appliance to
appliance. Consult the technician
for the proper size.

1
5-8(depending on models)

5-8(depending on models)

1

1

1
2

1

1

Except the above parts provided,the other parts needed during installation you must
purchase.

Remote controller holder

Number Name of Accessories

Qty

NOTE:

optional
parts

Indoor & outdoor unit installation drawings

The mounting plate should be installed on a wall
which can support the weight of the indoor unit.