2. Drill a hole in the wall

Wall

Indoor

Outdoor

5

-7

m

m

Fig.3

INDOOR UNIT INSTALLATION

1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five or eight 5mm
diameter holes in the wall.Insert Clip
anchor for appropriate mounting
screws.
3. Fit the installation plate on the wall
with five or eight type A screws.

Mount the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate provided
with the machine differ from
appliance to appliance.
(Dimensions are in mm unless
otherwise stated)

NOTE:

NOTE:

1. Installation Plate Mounting

The mounting wall is strong and solid
enough to prevent it from the vibration.

"

"

"

"

Correct orientation
of Installation Plate

Electric safety regulations for the initial Installation
1. If there is serious safety problem about the power supply, the technicians should refuse to
install the air conditioner and explain to the client until the problem is solved.
2. Power voltage should be in the range of 90%~110%of rated voltage.
3. The surge protector and main power switch with a 1.5 times capacity of Max. Current of the unit
should be installed in power circuit. Ensure the air conditioner is grounded well.
4. The appliance shall be installed in accordance with national wiring regulations. Do not operate
your air conditioner in a wet room such as a bathroom or laundry room.
5. An all-pole disconnection device which has at least 3mm clearances in all poles, and have a
leakage current that may exceed 10mA, the residual current device(RCD) having a rated
residual operating current not exceeding 30mA, and disconnection must be incorporated in the
fixed wiring in accordance with the wiring rules.
6. For the unit adopts auxiliary electric heater, keep at least 1 meter away from the nearest
combustible materials.
7. According to the attached Electrical Connection Diagram located on the panel of the indoor &
outdoor unit to connect the wire.
8. All wiring must comply with local and national electrical codes and be installed by qualified and
skilled electricians.
9. An individual branch circuit and single receptacle used only for this air conditioner must be
available. See the following table for suggested wire sizes and fuse specifications:

Minimum cross-sectional area of conductors:

Electrical work

3. Connect the cable to the indoor unit

The wire size of power supply cord
and interconnected wire and the
current of the fuse or switch are
determined by the maximum current
indicated on the nameplate which
located on the side panel of the unit.
Please refer to the nameplate before
selecting the wire size, fuse or switch.

The controller of the air conditioner
designed with a fuse protection
function under abnormal conditions,
the specifications of the fuse have
printed on the circuit board, such as:
T3.15A/250VAC, T5A/250VAC, etc.

NOTE:

INDOOR UNIT INSTALLATION

INDOOR UNIT INSTALLAITON

Fig.2

1. Determine hole positions according to left
and right side of the installation plate. The hole
center is obtained by measuring the distance as
shown in the diagram of Fig.2.
2. Dirll the piping plate hole with

65mm hole-core drill.

3. Drill the piping hole at either the right or the left and
the hole should be slightly slanted to the outdoor side,
see Fig.3.
4. Always take steps to protect the pipe when drilling
metal grid,metal plate or the like.

NOTE:

To protect the front panel of the indoor unit
during transportation, the adhensive tape
have been put on in the factory as shown in
the picture. Please remove all the tape
before installation.

Model A(A:900, B:290, C:83, D:170)
Model B(A:1045, B:305, C:100, D:170)

Model A(A:900, B:290, C:83, D:170)
Model B(A:1045, B:305, C:100, D:170)

120mm or

more to wall

120mm or

more to wall

A

A

B

B

1

1

5

.4

1

1

5

.4

1

1

5

.4

1

1

5

.4

4

3

4

3

4

3

4

3

C

C

D

D

150mm or more to ceiling

Adhensive tape

150mm or more to ceiling

Left rear side

refrigerant

pipe hole 65

Left rear side

refrigerant

pipe hole 65

Right rear side

refrigerant

pipe hole 65

Right rear side

refrigerant

pipe hole 65

Indoor unit outline

Indoor unit outline

120mm or

more to wall

120mm or

more to wall

6

5

Appliance Amps

AWG Wire Size

10

13

18

25

18

16

14

12

30

40

10

8