Т³гж 6 – Pridiom Elite Series PWS247EL Installation Manual User Manual

Page 6

Advertising
background image

9

9

10

10

Refrigerant pipe connection

Oblique

90

Roughness

Burr

Main cause for refrigerant leakage is due to defect
in the flaring work. Carry out correct flaring work
using the following procedure:
A: Cut the pipes and the cable.
1. Use the piping kit accessory or pipes
purchased locally.
2. Measure the distance between the indoor
and the outdoor unit.
3. Cut the pipes a little longer than the
measured distance.
4. Cut the cable 1.5m longer than the pipe length.

1. Flaring work

Fig.11

Fig.12

Drain joint installation

Seal

Drain joint

Base pan hole of
outdoor unit

Seal

Drain pipe

(A)

(B)

For the drain joint with the seal(Fig.11 (A)), first
fit the seal onto the drain joint, then insert the
drain joint into the base pan hole of outdoor unit,
rotate 90

to securely assemble them. To install

drain joint as shown in Fig.11 (B), insert the drain
joint into the base pan hole of outdoor unit until it
remains fixed with a clicking sound. Connecting
the drain joint with an extension drain hose (Locally
purchased), in case of the water draining off the
outdoor unit during the heating mode.

NOTE: The drain joint is slightly different
according to the different outdoor unit.

Outdoor unit dimension
mm(WxHxD)

A(mm)

458

460

B(mm)

250

276

530

549

290

325

560

481

335

276

549

276

Mounting dimensions

700x540x240

685x430x260

780x540x250

760x590x285

810x558x310

845x700x320

670x540x265

Anchor the outdoor unit with a bolt and nut 10 or

8 tightly and horizontally on a concrete or rigid mount.

Settlement of outdoor unit

NOTE: The outdoor unit you purchase may be like one
of the following. Install the outdoor unit according to the
dimension as indicated in the table below:

A

W

B

D

Air inlet

Air outlet

Air inlet

Fig.8

Install the outdoor unit on a rigid base to
prevent increasing noise level and vibration.
Determine the air outlet direction where the
discharged air is not blocked.
In the case that the installation place is exposed
to strong wind such as a seaside, make sure the
fan operating properly by putting the unit lengthwise
along the wall or using a dust or shield plates.
Specially in windy area, install the unit to prev-
ent the admission of wind. If need suspending
installation, the installation bracket should
accord with technique requirement in the
installation bracket diagram.
The installation wall should be solid brick,
concrete or the same intensity construction, or
actions to reinforce, damping supporting should
be taken. The connection between bracket and
wall, bracket and the air conditioner should be
firm, stable and reliable.
Be sure there is no obstacle which block
radiating air.

Fig.9

OUTDOOR UNIT INSTALLATION

Outdoor installation precaution

1. Pass the piping through the hole in the wall.
2. Hook the indoor unit onto the upper portion
of installation plate(Engage the indoor unit with
the upper edge of the installation plate). Ensure
the hooks are properly seated on the installation
plate by moving it in left and right.
3. Piping can easily be made by lifting the indoor
unit with a cushioning material between the
indoor unit and the wall. Get it out after finish
piping.
4. Press the lower left and right side of the unit
against the installation plate until hooks
engages with the their slots.

Indoor unit installation

Strong
wind

Strong
wind

Barrier

Incorrect

Correct

OUTDOOR UNIT INSTALLATION

OUTDOOR UNIT INSTALLATION

Fig.10

NOTE: Connective pipe length will affect the
capacity and energy efficiency of the unit. The
nominal efficiency is tested basing on the pipe
length of 5 meters.

Advertising