Nicd sensitivity deltav default, Temp. cut-off on 50, Safety timer on 120min – ProgressiveRC 1010B+ iCharger User Manual
Page 10: Capacity cut-off on 5000mah, Watt limit (w) chg:auto dchg:20, Nimh/nicd check delay 0min
 
 
 
-10-
iCharger Synchronous Balance Charger/Discharger 1010B+
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NiCd Sensitivity 
DeltaV Default 
Inc
Dec
-
Dec
+
Inc
Usually, the NiCd battery voltage will drop a little right after reaching full 
charge. This is known as -△V. You can alter the iCharger‘s delta-peak 
detection sensitivity. 
Range: 1 – 20mV/Cell. (8mV/Cell, default)
 
 
When NiMH&NiCd batteries are deeply discharged or left unused for a long 
time, they will produce a false -△V which stops charging early. You can 
disable -△V testing to avoid this problem. 
Range: 0 –
30min (0, default)
 
 
Battery upper temperature limit. The battery temperature can be monitored 
with the attached temperature sensor. In order to protect the battery from 
damage due to high temperatures the iCharger will stop charging or 
discharging immediately if the temperature exceeds the cut-off setting. 
Users can choose ℃ or 
o
F as the temperature unit
Range: 20 –
80℃(68 –
176
o
F).
o
F = (9/5)×℃+32.
 
Charging time upper limit. The charging process will stop immediately if it 
exceeds the set value. 
Range: 1 –
999min
 
 
 
Capacity protection. The charging/discharging process will stop immediately 
if the calculated charge input/drained exceeds the set value. 
Range: 100 –
99900mAh
 
 
 
Input voltage protection lower limit. The charging/discharging process will 
stop immediately if the input voltage falls below the set value. 
Range: 10.00 – 15.00V (10.00V, default) 
Current Range: 1.0A – 22.0A(22.0A, default) 
Note: Current limit is not very accurate, which may be 20% difference, max.
 
Charge/Discharge power limit. The maximum charge/discharge power of 
iCharger can be adjusted in order to limit internal temperature and to
protect the input current from over-loading
. When the limit is set to AUTO
the iCharger can adjust the output charging power according to the input 
capability. 
CHG: 50 –300W and AUTO. DCHG: 5 –30W 
 
Note: The maximum charge power capacity is also limited by input current. 
The maximum input current of 1010B+ is about 24A, and Wmax ≈ Imax * 
Vin * 90%. (For example, when the input voltage is 11V, the maximum 
charge power capacity ≈24Ч11Ч90%=238W). 
Temp. Cut-Off 
ON 50℃ 
-
Dec
+
Inc
Safety timer 
ON 120min 
Capacity Cut-Off 
ON 5000mAh 
Watt Limit (W) 
CHG:AUTO DCHG:20 
Inc
Dec
Inc
Dec
NiMH/NiCd Check 
Delay 0min 
Inc
Dec
Inc
Dec
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
NiCd Sensitivity 
DeltaV Default 
-
Dec
+
Inc
Inc
Dec
Inc
Dec
Inc
Dec
iCharger1010B+: MAX. OUTPUT POWER vs. INPUT VOLTAGE
200
220
240
260
280
300
320
10
11
12
13
14
Input voltage(V)
Ma
x.
O
u
tp
u
t p
o
w
e
r(W
)
Input limit 22.0 
Cut-Off 4.50V 
-
Dec
+
Inc