Program select settings, Bal.speed normal bal.trickle off, Lithium battery check time 1min – ProgressiveRC 1010B+ iCharger User Manual
Page 9: Wait time chg/dchg 10min, Nimh sensitivity deltav default, Nimh/nicd/pb trickle off, Li balance on cv phase
 
 
 
-9-
iCharger Synchronous Balance Charger/Discharger 1010B+
Parameter setup
Users should check the parameter settings and adjust the parameter values according to the specifications of 
the pack to be charged or discharged. 
 
Note: The screen diagram on the left shows the system‘s default setting.
 
 
 
User parameter setup initial display. 
 
 
 
iCharger checks the cell count of Lithium batteries automatically at the 
beginning of the charge or discharge process in order to detect and avoid 
erroneous setting by the user. However, deeply discharged batteries can be 
perceived incorrectly. To avoid this problem you can set an initial time during 
which to charge the battery at a low current, usually 100mA. Normally 10 
minutes is enough to detect the cell count correctly. For batteries of different 
capacities, you should adjust the time delay. Note: If you set the time delay 
too long for a low capacity battery then the charging process can be finished 
within the time delay with an erroneous cell count, which may damage the 
battery and could be dangerous. 
Range: 1 –
10 min. (1min, default)
For balance charging Lithium batteries. If the Bal. Speed is set to Fast, the 
CV termination current will be higher, the charging time shorter and the 
per-cell voltage lower. When set to Slow, the CV termination current will be 
lower, the charging time longer and the per-cell voltage higher. The default 
value of Normal is between the Fast and the Slow. If Bal. Trickle is ON, the 
iCharger won‘t stop charging until the current falls to around 20mA. 
Bal.Speed: Fast, Normal & Slow, (Normal, default). 
Bal.Trickle: OFF & ON: (OFF, default) 
For balance charging Li battery. There are three balance modes options: CV 
phase, storage voltage and always. If the balance mode is set to CV phase, 
when any cell‘s voltage reaches the set voltage for CV, it will enable the 
balancer. When set to ―always‖, the balancer will be enabled from the 
beginning of the charge process. When set to ―storage voltage‖, the 
balancer will be enabled when any cell‘s voltage exceeds the default storage 
voltage for the configured chemistry. 
Balance mode: CV phase, storage voltage, always (CV phase, default)
 
When running a charge/discharge cycle program for a Lithium, NiMH or 
NiCd battery the charger will stop for a while before continuing to the next 
phase. This allows the pack to cool down. 
Range: 1
–
60 min. (10 min default)
 
 
You can turn post charge-completion trickle charging. On or Off for NiMH, 
NiCd or Pb batteries. 
Range: OFF, 10 –
500mA. (OFF,default)
 
 
 
Usually, the NiMH battery voltage will drop a little right after reaching full 
charge. This is known as -△V. You can alter the iCharger‘s delta-peak 
detection sensitivity. 
Range: 1 –
20mV/Cell. (4mV/Cell, default)
 
 
PROGRAM SELECT 
Settings ->
Start/Enter
Inc
Dec
Bal.Speed Normal 
Bal.Trickle OFF 
Inc
Dec
Lithium battery 
Check Time 1min 
-
Dec
+
Inc
-
Dec
+
Inc
Inc
Dec
Wait Time 
CHG/DCHG 10min 
NiMH Sensitivity 
DeltaV Default 
NiMH/NiCd/Pb 
Trickle OFF 
Inc
Dec
Inc
Dec
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc
Li Balance ON 
 CV phase 
-
Dec
+
Inc
Dec Inc