Discharging a Lithium battery
In this mode, you can set the target per-cell voltage and hence the final voltage (final voltage=cell 
voltage*number of cells). The lowest allowable cell voltage depends on the type of Lithium battery: 2.50V for 
Lilo, 3.00V for LiPo and 2.00V for LiFe per cell. If the battery is connected to the balance port, the iCharger 
can monitor the individual cell voltages. The discharge will stop immediately if any cell falls below the 
configured final voltage. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Note: If you connect the balance port at the beginning of the discharging process, then the balance port will 
monitor each cell‘s voltage, if one of these cells‘ voltage reaches the termination voltage then the process will 
terminate with ―balance port low cel vol‖. For example in LiPo mode, if one cell‘s voltage reaches 3.0V the 
process will stop. 
 
If you want to avoid this ―balance port low cell vol‖ message, then you can connect the balance port after the 
discharge process has started. In that case the process won‘t monitor each cell‘s voltage, just the pack‘s 
voltage and the discharge process will terminate when the pack voltage reaches the termination voltage (= 
target_cell_voltage x number_of_cells). For example in LiPo mode, the discharge process won‘t terminate 
until the pack‘s voltage reach N*3.0V. 
Discharge Lithium battery. The left side of the first line set the type of battery 
(LiPo, Lilo or LiFe) and the value on the right side shows the final discharge 
voltage of each cell. The value on the left side of second line sets the 
charge current and the value on the right side of second line sets the cell 
count and voltage of the battery pack. After setting the current and voltage, 
press Start/Enter for more than 3 seconds to start the next process. 
Per-cell final voltage:
LiPo (3.00 – 4.20V), Lilo (2.50 – 4.10V), LiFe (2.00 – 3.60V)
Discharge current: 0.05 – 7A , Cell count: 1 – 10S
The number of cells you set and the processor detects. If the checking 
result is the same, it would enter to the next interface; if not the same, the 
left side of the first line ‘R:xxSER‘ shows the number of cells detected by the 
iCharger and the right side of the first line ‘S:xxSER‘ is the number of cells 
set by the user. Usually, the auto-detect number won‘t lower than the 
number set by the user. You should make sure that the configured number 
and the actual number for the battery are the same and then you can start 
charging by pressing Start/Enter. If not, press Batt type/Stop to go back to 
the previous screen and adjust the setting. 
Discharge process. The iCharger allow its user to alter the discharging 
current during the process. Press Start/Enter to make the discharge current 
blink then press Inc to increase or press Dec to decrease the value and 
press Start/Enter to confirm the alteration. You can stop discharging at any 
time by pressing Batt type/Stop. Press Inc to display each cell‘s voltage 
(see the balance voltage information) and press Dec to display the 
General Status information. 
 
LiPo DCHG 3.30V 
1.0A 11.1V(3S)
Start/Enter
>3 seconds 
 
Batt type
stop
R:04SER S:03SER 
CONFIRM(ENTER)
Start/Enter 
 
Batt type
stop
Battery
Series
V-BP
Charge
Current
Li03 1.0A 12.60V 
DSC 00993 59m:51 
battery
voltage
number
of cells
Series
discharge
capacity
discharging
time
discharge
current
work
state
-
Dec
+
Inc
-
Dec
+
Inc
-
Dec
+
Inc